Compact power and signal transfer
The ByTune BTH1235 transfers electrical power and signals between stationary and rotating equipment through continuous 360° rotation. Its central opening leaves a route for a shaft or service lines, while the 35 mm outer diameter suits assemblies with limited radial space.
Choose 6 or 12 electrical circuits at 2A per circuit. Precious metal contacts carry the electrical paths across the rotating interface, avoiding the cable winding that would occur with a fixed connection. The working speed is 500 rpm.
6 and 12 circuit dimensions


| Configuration | Circuits | Body length | Bore diameter | Outer diameter |
| 6 circuit version | 6 | 23.6 mm | 12.7 mm | 35 mm |
| 12 circuit version | 12 | 37.4 mm | 12.7 mm | 35 mm |
Body length changes with the circuit count. Allow additional axial space for the lead exits, cable bends and cable restraints; the body dimensions do not include the complete installed wiring envelope. The 200 mm leads also need enough reach to the stationary and rotating connection points.
Open the 23.6 mm outline drawing to view the dimensions at full size.
For a replacement, match the bore fit, body clearance, mounting arrangement and lead routing as well as the circuit count. Equal bore and outer diameters alone do not establish interchangeability.
Electrical and mechanical specifications
| Parameter | BTH1235 specification |
| Circuits | 6 or 12 |
| Current rating | 2A per circuit |
| Voltage | ≤380V |
| Working speed | 500 rpm |
| Operating temperature | −40°C to +100°C |
| Contact material | Precious metal |
| Protection rating | IP54 |
| Dielectric strength | ≥1,000V at 50Hz between circuits |
| Insulation resistance | 1,000MΩ at 500VDC |
| Electrical noise | ≤7mΩ |
| Lead wire | 26 AWG; coloured PTFE insulation; silver- or tin-plated conductor |
| Lead length | 200 mm |
The current rating applies to each electrical path. Budget motor starting currents and other peaks separately from the normal running load. Dielectric strength and insulation resistance are insulation test values; they do not increase the operating voltage rating.
The electrical noise figure is expressed as a resistance value. Signal selection also depends on the interface, data rate, cable construction and shielding; this figure alone does not establish data link performance.
Plan the wiring and installation
Count the complete wiring arrangement, including power supply and return conductors, signal pairs, references and any dedicated shield or earth paths. Six circuits do not necessarily provide six independent powered devices. Reserve separate paths where the equipment design requires them.
For a gimbal, small robot joint or antenna positioning assembly, identify the low power loads and control signals that cross the rotating joint. Digital communication, video and encoder signals need a configuration review against the actual interface, data rate, cable construction and shielding requirements.
Match the shaft fit and retention method to the assembly drawing. Restrain the stationary side without pulling on its leads, and keep both lead bundles clear of moving parts. Before powered operation, inspect the wiring, verify continuity and insulation, and check that rotation is free of binding. See the through hole slip ring installation guide for the general preparation sequence.
If intermittent signals, unusual heating or binding develops, isolate the equipment before inspecting the mounting, cable restraints and electrical connections. Share the operating conditions and symptoms with ByTune for troubleshooting.
Where this compact slip ring fits
Consider BTH1235 for compact gimbals, small robotic mechanisms and antenna positioning assemblies where the central opening and radial clearance suit the design. Select the electrical paths for the actual load and control interface. An antenna application may need a separate RF rotary joint; an electrical circuit rating is not an RF frequency rating.
A rotating test fixture or pan and tilt monitoring mechanism can use a slip ring to connect low power devices across its rotating interface. Define the sensor output, sampling requirements and interference environment when selecting the wiring. The 500 rpm speed and 2A circuit rating set the starting limits for this model.
For a different bore or a larger electrical load, compare the relevant BTH1256 configuration or browse the through hole slip ring range.
Request a BTH1235 configuration
Send the required quantity, circuit allocation, voltage and current for each path, operating speed, duty cycle and installation drawing. For a replacement, include the existing part label, connector or lead details and the space available around the rotating joint. ByTune can review these requirements against the standard configurations or a custom design.
For purchasing, include the sample or production quantity and required delivery date. The quotation can then address the selected configuration, pricing and delivery schedule.
ByTune provides slip ring design and manufacturing support for mechanical fit, circuit layout and connection requirements. Discuss lead length, termination and interface needs with the engineering team; changes to the standard configuration are evaluated for the application.
Inspection planning can cover dimensions, continuity, insulation and rotation, with signal checks defined for the intended interface. See ByTune quality control and testing. Include service life targets, environmental conditions and any required compliance documents in the enquiry so the team can define the inspection and documentation scope.
Send Your BTH1235 Requirements
Application Scenario
You may find small through hole slip ring used in the following industries:

Wind power generation
The blades of the wind turbine are rotating, while the electrical equipment inside the tower is stationary. The slip ring is used to transmit power and signal communication between the blade pitch control system and the control cabinet inside the tower.

Monitoring system
When the pan/tilt rotates, the slip ring helps the camera's video signal and possible control signals (such as zoom, focus, etc.) to be transmitted to the fixed monitoring terminal device.

Amusement facilities
It can transmit ground power to the rotating Ferris wheel structure, provide power for the amusement facility, and help monitor its operating status in real time.

Testing and measurement
When the motor rotates at high speed, we measure the temperature, vibration and other parameters of the rotor, while providing power to its auxiliary equipment. The slip ring is used to transmit the sensor signal for the test work.
FAQ
Hot Tags: Small Through Hole Slip Ring, China Small Through Hole Slip Ring manufacturers, suppliers, factory,BTH1235 through hole slip ring,12.7mm through hole slip ring, High Temperature Military Standard Through Hole Slip Ring, High Speed Standard Through Hole Slip Ring, anti vibration through bore slip ring, Small Through Hole Slip Ring For Precise Instrument, Anti-vibration Through Bore Slip Ring, Through Hole Slip Ring For Satellite Antenna